A current transformer (CT) is an instrument transformer that reduces or multiplies alternating current (AC), producing a secondary winding with a current proportional to the primary winding.current transformer for panel meter This type of transformer is used in many applications, including electricity metering and protective relaying.
When properly connected to a panel meter, a current transformer turns the AC current from the mains into a DC output that is read by the panel meter.current transformer for panel meter This is possible because the secondary of a CT has a very low resistance. As a result, the current through the secondary is proportional to the primary current — with a ratio that is usually approximately equal to 1:5 or 5:1.
A CT has one or more flat or round primary windings with multiple turns of heavy copper wire around a core of some sort. Depending on the type of CT, the core may be a toroidal shape with two ends or it may have a split section that allows it to be wrapped around a conductor without disconnecting it first.
Most CTs are rated for high voltage, with a maximum of 800 Amps and a primary to secondary ratio of 20:1. The secondary of the CT will produce an AC output at its peak frequency. This can be either a DC current output or a 4-20mA output. The secondary current is a function of the primary current and can be used to calibrate the ammeter to give an accurate reading.
The main reason for a high voltage rating on a current transformer is that there is almost no opposition to the magnetic field created by the primary current in the secondary windings, which allows a high number of turns to be placed in the secondary. A high number of turns creates a large amount of energy in the secondary, which can generate a dangerous high voltage.
Many panel meters, watt-hour meters and protective relays require a current transformer to measure AC current. A typical CT has a primary conductor that passes through the center of the transformer and a secondary conductor that connects to the meter. The primary conductor is typically a ring-type or donut-type.
Clamp meters can also be a type of CT that has one or more removable sections of the core, allowing them to be placed around a conductor without disconnecting it. These types of CTs can have a single-turn ratio and are available in various sizes. They can also be designed for higher ratios and be used in non-standard applications such as ground fault detection. Some clamp CTs are designed with a plastic molded case, while others have a bare metal core for higher voltages and a ring-type CT for use in metering applications in switch gear. Some of these CTs have a secondary winding with more than one turn, and can be used to detect three-phase currents or other special requirements.